Limb Reconstructions > Blog > Clinical Blog > Aiming in Tibio > Part 3 (29 October 2018) – Aiming in Tibio-Calcaneal Fusion Using Fine Wire Frame
Part 3 (29 October 2018) – Aiming in Tibio-Calcaneal Fusion Using Fine Wire Frame

During the revision surgery 6.5mm cancellous cannulated screw was inserted paying significant attention to where it should be positioned. At this moment I am not aware of the best docking for the tibia – should it dock on calcaneum only or should it dock on calcaneum and navicular.
New foot plate was attached. The docking site was not addressed as per standard procedure.


calcaneum cancellous screw docking site fine wire frame foot plate attachment limb reconstruction navicular orthopedic surgery orthopedic techniques revision surgery tibio-calcaneal fusion

Author: Matija Krkovic
Website: https://www.limbreconstructions.com/