Patient’s activity level has improved significantly, with no major pin site issues apart from one broken pin, which was removed in the clinic. CT scan confirms further progress toward union. Follow-up in six weeks to assess frame dynamisation.
Knee stability has improved, and pain is subsiding. Pin sites remain in good condition, with X-rays showing continued progress toward union. A CT scan is planned in two months to confirm further healing.
Leg alignment continues to improve with no significant increase in pain. Pin sites remain clean, and the frame is stable. The next follow-up is scheduled in four weeks.
Leg alignment is nearing normal after correcting 7 degrees of valgus, but knee pain has increased. The plan is to continue the correction into slight varus to improve knee function while monitoring pain levels.